Fire
Medline Updates Customers and Patients on Repair and Replace Program for Recall of Medline Brand Beds, Rails, Mattresses and Accessories
Hazard (FDA): Potential Fire Hazard and Entrapment Risk
FDAMedical devices
INTELERAD MEDICAL SYSTEMS INCORPORATED: intelerad IntelePACS software
Hazard (FDA): A cybersecurity vulnerability has been identified in the software that could allow a malicious user to take over an administrator session, delete or modify image or study data, or lock legitimate users out of the…
FDAMedical devices
Sterility
AVID Medical, Inc.: Halyard MINOR PACK. Model/Catalog Number: VASF105-08.
Hazard (FDA): Potential for open seals on header bags, compromising sterility.
FDAMedical devices
Mislabeled
AVID Medical, Inc.: Halyard ARTHROSCOPY PACK. Model/Catalog Number: SAMM014-21.
Hazard (FDA): Shelf label of kit is mislabeled as "Extremity" instead of "Arthroscopy Pack."
FDAMedical devices
CORIN MEDICAL, LTD.: Unity Knee ASC Modular Handle included in the Corin UNITY ASC INSTRUMENT SYSTEM. Part…
Hazard (FDA): Potential malfunction of the Modular Handles where the locking mechanism may fail. Any mating instruments already engaged to the handle will not be able to be disengaged, and the handle will be unable to fitted…
FDAMedical devices
Illumina, Inc.: Nextseq 550Dx Instrument REF: 20005715 and 4 more
Hazard (FDA): (Retrospectively reported) Cybersecurity vulnerability identified in communication protocol between the customer-provided infrastructure (network storage, servers, or computers) and in vitro diagnostic devices which…
FDAMedical devices
NATUS MEDICAL INCORPORATED: Embletta MPR PG Multi Parameter Recorder Sleep Monitor
Hazard (FDA): The device may be unable to correctly format its internal memory. When the internal memory cannot be correctly formatted, previously recorded studies may remain on the device and may be updated with incorrect patient…
FDAMedical devices
Smith & Nephew, Inc.: EVOS 3.5MM LATERAL PROXIMAL TIBIA PLATE 6 HOLE LEFT 91MM REF72463106
Hazard (FDA): Incorrect labeling; 3.5MM Partial Articular Lateral Proximal Tibia Plate 6 hole Left 91MM implant labeled and lasered etched as as 3.5MM Lateral Proximal Tibia Plate 6 hole left 91mm implant
FDAMedical devices
Accriva Diagnostics, Inc.: Hemochron Jr.
Hazard (FDA): Microcoagulation test used to evaluate low dose heparin anticoagulation has a mispositioned or absent clot activating reagent, which may result in out-of-range high error code, or erroneously high results, which may…
FDAMedical devices
Tandem Diabetes Care, Inc.: Tandem Mobi Insulin Pump
Hazard (FDA): Tandem Diabetes Care, Inc. ( Tandem ) has identified that certain Tandem Mobi insulin pumps may generate false-positive occlusion alarms when no actual insulin flow obstruction is present. Investigation determined that…
FDAMedical devices
Baxter Healthcare Corporation: TruSystem 7000 U Operating Table and 1 more
Hazard (FDA): The main lift may unexpectedly drop from its set position to its lowest position during use. The tabletop may not be able to be raised again after the drop occurs. An uncontrolled drop of the surgical table may result…
FDAMedical devices
Remel, Inc: Yeastone Broth
Hazard (FDA): Affected lot did not meet specifications. Product may report false susceptibility to antifungal agents, specifically within the Azole family.
FDAMedical devices
Baxter Healthcare Corporation: TruSystem 7500 surgical table and 4 more
Hazard (FDA): There is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop…
FDAMedical devices
Cochlear Limited: Cochlear Nucleus Nexa cochlear implant with Contour Advance electrode REF P1979576 Model…
Hazard (FDA): Due to a manufacturing deviation of incomplete electrode welds of cochlear implants and resulting in one or more open circuits
FDAMedical devices
GE Medical Systems, LLC: Senographe Pristina and 2 more
Hazard (FDA): GE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisition configuration of the anode track/filter combination is…
FDAMedical devices
Edwards Lifesciences, LLC: Generic Name: Edwards Commander M Delivery System Generic Name: Edwards Commander M…
Hazard (FDA): Due to a manufacturing issue which may result in cardiovascular balloon rupturing.
FDAMedical devices
Cardinal Health 200, LLC: Cardinal Health Presource PBDS kits and 10 more
Hazard (FDA): Kits contain infusion sets which were recalled for performance issues.
FDAMedical devices
restor3d Inc.: Veritas Reverse Total Shoulder Replacement
Hazard (FDA): (Retroactively reported) Pairing of shoulder implant stem sizes 1 and 2 with the largest glenosphere diameter (40 mm) creates an excessive mechanical loading configuration in which certain polyethylene components lack…
FDAMedical devices
SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION: Trinias Opera Smart
Hazard (FDA): The mounting bolts securing the C-arm drive unit of the X-ray system may not be torqued to specification, potentially compromising structural stability and safe operation.
FDAMedical devices
Luminex Corporation: LIAISON PLEX Gram-Negative Blood Culture Assay Catalog No. 20-005-303
Hazard (FDA): Instructions for Use updated to include explicit guidance that repeat testing is recommended whenever a positive family-level only result is obtained. Issue may contribute to incorrect or delayed diagnosis of…
FDAMedical devices
Henry Schein Inc.: Generic Name: Perma Sharp Sutures and 12 more
Hazard (FDA): Products lack 510(k) clearance.
FDAMedical devices
Artivion, Inc: CryoPatch SynerGraft
Hazard (FDA): A cryopreserved pulmonary human cardiac patch, taken from a 64-year-old human donor, was outside the cardiac tissue donor age specification of newborn to 60 years. The patch was implanted, and due to limitations of…
FDAMedical devices
ZIEHM-ORTHOSCAN INC: Orthoscan VERSA Accessory Cart
Hazard (FDA): The accessory cart weldment does not conform to weld dimensional specifications which may result in separation of the monitor arm mounting structure from the cart.
FDAMedical devices
Medtronic, Inc.: OmniaSecure Model 3930M
Hazard (FDA): Affected leads require additional engineering evaluation due to complaints regarding difficulty in achieving fixation during implantation. Potential harm of tissue trauma due to implant difficulty.
FDAMedical devices
- FDAEthicon, LLC: ETHILON Nylon Suture
- FDAPHILIPS MEDICAL SYSTEMS NEDERLAND B.V.: Philips Azurion 3 M12. Model Numbers: 722063 and 8 more
- FDABioMerieux SA: EMAG system Model/Catalog Number: 418591/418591U Product Description: Nucleic acid…
- FDAARJOHUNTLEIGH POLSKA Sp. z.o.o.: Carevo
- FDACanon Medical System, USA, INC.: ALPHENIX INTERVENTIONAL ANGIOGRAPHY SYSTEM REF: INFX-8000C and 2 more
- FDAStryker Leibinger GmbH & Co. KG: Precision Pointer Electromagnetic
- FDABoston Scientific Neuromodulation Corporation: Nalu TD2 Therapy Disc with firmware
- FDAPentax of America Inc: PENTAX Medical Ultrasound Endoscope. Model Number. EG36-J10UR. and 4 more
- FDAAbiomed, Inc.: Automated Impella Controller and 2 more
- FDAPhilips North America: Model Number: 712010.
- FDAMedtronic, Inc.: CareLink SmartSync Programmer and 2 more
- FDAAVID Medical, Inc.: Halyard ANTERIOR HIP PACK. Model/Catalog Number: SOAH31. and 1 more
- FDAMedline Industries, LP: MEDLINE DRAPE C-SECTION W/POUCH ST 7/CS and 12 more
- FDASolstice Corporation: Xact mole marker for mammography Model/Catalog Number: M15RM
- FDAMedtronic Neuromodulation: InterStim SureScan MRI Leads 978A1 & 978B1: LEAD 978A128 ISTM MICRO 28CM SSMRI TINED… and 1 more
- FDAMedtronic MiniMed, Inc.: Generic Name: MiniMed Go App Generic Name: MiniMed Go App Model/Catalog Number: MMT-8600
- FDArestor3d Inc.: Generic Name: restor3d MTP Implant Generic Name: MTP Implant Model/Catalog Number…
- FDACooperVision, Inc.: Generic Name: Softmed Breathables Advanced Toric
- FDAPhilips North America: Philips Smart-hopping 2.0 AP 1.4 GHz
- FDAAxonics, Inc.: PNE Lead Implant Kit REF: 1701
- FDABoston Scientific Cork, Ltd.: Direxion Torqueable Microcatheter and 40 more
- FDAMedtronic Navigation, Inc.: Medtronic NDI Passive Spheres REF: 8801071 and 3 more
- FDALife Technologies Holdings Pte Ltd: Ion Torrent Genexus Dx with software
- FDABeckman Coulter, Inc.: ROTOR ASSY-SW40 and 1 more
- FDAB Braun Medical Inc: B Braun SAFSITE Injection Site
- FDAPhilips Ultrasound, LLC: Philips Lumify Diagnostic Ultrasound System
- FDAThink Surgical, Inc.: Think Surgical Square Driver REF: 109126
- FDAAbbott: Amplatzer Amulet Left Atrial Appendage Occluder Model Numbers 1. 9-ACP2-007-016 2…
- FDAVentec Life Systems, Inc.: VOCSN+Pro and 11 more
- FDAMedtronic MiniMed, Inc.: CareLink Clinic
- FDATECHNO-PATH MANUFACTURING LTD.: Techno-Path Multichem AE Unassayed Level 1 REF:AE621X and 2 more
- FDAGreiner Bio-One North America, Inc.: Brand Name: VACUETTE Product Name: LH Lithium Heparin Separator Model/Catalog Number…
- FDAMedline Industries, LP: Medline convenience kit labeled as: FOOT ANKLE. Medline Kit SKU DYNJ65395A
- FDAINTEGRATED MEDCRAFT LLC: FORWARD Gunshot Wound Kit
- FDAHealthmark Industries Co., Inc.: Vinyl Instrument Guards
- FDAMerit Medical Systems, Inc.: Scout MD
- FDAINTELERAD MEDICAL SYSTEMS INCORPORATED: IntelePACS
- FDAMedline Industries, LP: Convenience Kits containing CONMED AirSeal Access Ports ADVANCE LAPAROSCOPIC DYNJ911135… and 5 more
- FDAMedline Industries, LP: Medline surgical convenience kits labeled as: CABG AUXILIARY PACK and 11 more
- FDAHowmedica Osteonics Corp.: TS Universal Baseplate Finishing Tray and 3 more
- FDACook Incorporated: Williams Cystoscopic Injection Needles
- FDAW L Gore & Associates, Inc.: Generic Name: GORE VIABIL Short Wire Biliary Endoprosthesis
- FDASI-BONE, Inc.: iFuse TORQ Implant System Model/Catalog Number: 10055T
- FDAFerno-Washington Inc: Power F2 Powered Fastening System
- FDAIn2bones USA, LLC: REF: P65 ST862 CoLag SCREW
- FDAInstrumentation Laboratory: HemoslL AcuStar HIT-lgG and 1 more
- FDASarnova HC, Llc: Curaplex Capnography EtCO2/O2 Oral/Nasal Cannula Multipack
- FDABeckman Coulter, Inc.: DxU 840m Iris and 1 more
- FDABoston Scientific Corporation: NaviFlex LW Pusher
- FDANeuronetics, Inc.: NeuroStar Advanced Therapy System. Contains the NeuroStar HP Coil Assembly Part Number…
- FDASteris Corporation: RAPICIDE PA Part A High-Level Disinfectant and 2 more
- FDABaxter Healthcare Corporation: Likorall Overhead Lifts Product Code: 3121001 Product Description: LIKORALL 200 Product…
- FDAMagellan Diagnostics, Inc.: LeadCare II Blood Lead Test Kit. Model/Catalog Number: 70-6762.
- FDACadwell Industries Inc: Brand Name: IOMAX Product Name: IOMAX Cortical Module Model/Catalog Number: 190296-200…
- FDARadiometer Medical ApS: The ABL90 FLEX and ABL90 FLEX PLUS analyzers are intended for use by trained technologists
- FDAEthicon, LLC: PERMA-HAND Silk Black Braided Sterile Nonabsorbable Surgical Suture
- FDAMicrogenics Corporation: MAS Omni IMMUNE PRO Liquid Assayed Integrated Immunoassay Control
- FDABecton Dickinson & Co.: BD Phoenix Panel NMIC-312. Catalog Number: 449082. and 1 more
- FDAMedtronic Sofamor Danek USA Inc: Grafton" DBM and Grafton Plus" DBM contain demineralized human bone tissue combined with… and 1 more
- FDAJenavalve Technology Inc.: JenaValve Trilogy Delivery Catheter and 2 more
- FDABioFire Diagnostics, LLC: Generic Name: FilmArray¿ Pneumonia Panel Generic Name: FilmArray¿ Pneumonia Panel… and 2 more
- FDASteris Corporation: HexaVue Focus Integration System
- FDALeMaitre Vascular, Inc.: TufTex¿ Over-the-Wire Embolectomy Catheter
- FDAMindray DS USA, Inc.: ePM Series Patient Monitor. Patient Monitor Series: ePM 10M/ePM 12M/ePM 12MA/ ePM… and 7 more
- FDAIntellijoint Surgical, Inc.: Intellijoint Navigation System: Workstation G2 Configured
- FDAMedtronic MiniMed, Inc.: Brand Name: MiniMed Flex Product Name: MiniMed Flex Insulin Pump Model/Catalog Numbers…
- FDACanon Medical System, USA, INC.: Alphenix INFX-8000C/B5
- FDASafeguard US Operating LLC: Battle Bandage
- FDAGRI Medical & Electronic Technology Co., Ltd.: HALYARD Laparoscopy Comprehensive Pack II REF: 49332
- FDALimitless Cryo Spa LLC: Glypto Device
- FDAPOLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC: SEDIPLAST
- FDAAVID Medical, Inc.: DAVINCI TRUCUSTOM BUNDLE and 14 more
- FDAMedline Industries, LP: Rollator and 1 more
- FDACardinal Health 200, LLC: Presource Packs containing Medtronic Microstream Components: Intubation Kit Catalog…
- FDABeckman Coulter Inc.: DxC 500i Clinical Analyzer Modules: 1. DxC 500 AU Module w/ISE and 1 more
- FDADRG International, Inc.: Sperm Ab ELISA
- FDAPHILIPS MEDICAL SYSTEMS: Spectral CT and Spectral CT 7500 RT
- FDASteris Corporation: VERIFY Biological/Integrator Challenge Pack Model/Catalog Number: LCB006 and 5 more
- FDAOnkos Surgical, Inc.: Onkos Surgical Inc. My3D Personalized Pelvic Implant and 1 more
- FDAStryker Sustainability Solutions: BARD EP XT DECAPOLAR STEERABLE
- FDANihon Kohden America LLC: Product Name: Nihon Kohden CNS-6200 Series Central Nurse Station
- FDAMedical Action Industries, Inc. 306: Generic Name: Kit
- FDAQUANTUM OPS Inc: Brand Name: ADAPTABLE Beach Chair Product Name: Beach Chair surgical patient positioner…
- FDAPhilips North America Llc: Philips Medical Systems Technologies Ltd. Spectral CT 7500
- FDAPhilips North America: Ingenia Blue Seal SE and Blue Seal XE and 11 more
- FDAMedline Industries, LP: Medline Basic Homecare Beds and Medlite Homecare Beds and Accessories and 1 more
- FDANOXBOX LTD: NOxBOXi Nitric Oxide Delivery System. Model Number: NOXBOX-I.
- FDADraeger, Inc.: VentStar Resus Neo. Neonatal. 25 Units per Box. Part Number: MP00310 Disposable…
- FDAOlympus Corporation of the Americas: Olympus M3 Gold Autoclavable Foroblique Telescope 30. Model Number: M3-30A. and 1 more
- FDACardinal Health 200, LLC: Presource Packs Containing Stryker StrykeFlow PS and AHTO tube sets: 1) KIT and 3 more
- FDAAmerican Contract Systems Inc: Medical convenience kits containing BD CliniClean Pericare Wipes within BD Urinary… and 2 more
- FDAAmerican Nitrile Operations Llc: Brand Name: Performance Pro Product Name: Performance Pro Model/Catalog Number: 72-RM50601 and 2 more
- FDAShanghai United Imaging Healthcare Co., Ltd.: Computed Tomography X-ray System and 11 more
- FDAVolcano Corp: Philips IntraSight Plus REF: 797423 and 797417 100-120v-220-240v
- FDASiemens Healthcare Diagnostics, Inc.: Atellica CH Revised C-Reactive Protein
- FDAHeraeus Medical GmbH (Dental Division): PALACOS R pro 40 and 3 more
- FDACustom Interventional Pain Management, LLC: Brand Name: Ferndale Laboratories
- FDAMicro Therapeutics, Inc.: Pipeline Flex Embolization Device with Shield Technology REF PED2-300-12 UDI-DI code…
- FDAASP Global, LLC.: Brand Name: Expressaire Product Name: DISPOSABLE TOURNIQUET CUFF and 63 more
- FDAWright Medical Technology, Inc.: CHARLOTTE CLAW Screw
- FDAPercussionaire Corporation: Intrapulmonary Percussive Ventilation and 6 more
- FDAPenumbra Inc.: Brand Name: Penumbra System
- FDABard Peripheral Vascular Inc: EnCor EnCompass Breast Biopsy and Tissue Removal System Console
- FDATandem Diabetes Care, Inc.: Brand Name: Tandem t:slim mobile application Product Name: t:slim Mobile Application
- FDABeckman Coulter Mishima K.K.: Systems/units containing affected software/SQL BECKMAN COULTER CHEMISTRY ANALYZER AU480…
- FDAKarl Storz Endoscopy: HOPKINS Telescope 30¿
- FDAIllumina, Inc.: NovaSeq 6000Dx including DRAGEN Server
- FDAMerit Medical Systems, Inc.: Embosphere 500-700 micrometer 2 mL Syringe Sterile Steam
- FDAOlympus Corporation of the Americas: Olympus Tripp-Lite P580-025 25ft DisplayPort Cable
- FDASPECTRUM MEDICAL SRL: Brand Name: Quantum PureFlow Product Name: Quantum PureFlow Standard Heat Exchanger High… and 1 more
- FDAAlere San Diego, Inc.: McKesson CONSULT hCG Urine Cassette and 3 more
- FDAHeartSine Technologies Ltd: HeartSine samaritan PAD
- FDANova Biomedical® Announces Global Medical Device Correction for StatStrip® Glucose Hospital Meter
- FDAPhilips North America Llc: Achieva 1.5T and 11 more
- FDACooperVision, Inc.: Brand Name: Pearle Vision 1 day Product Name:
- FDAAVID Medical, Inc.: Halyard IV START KIT NON-STERILE and 1 more
- FDAAVID Medical, Inc.: Halyard IV START KIT NON-STERILE
- FDANew York Embroidery Studio, Inc.: New York Embroidery Studio Trinity Non-Surgical Isolation Gown
- FDABiomerieux Inc: VITEK 2 AST-N461 TEST KIT
- FDAAbiomed, Inc.: Automated Impella Controller
- FDAINTERVASCULAR, SAS: Cardioroot Woven Collagen Coated Vascular Graft
- FDAMedline Industries, LP: Medline Convenience Kits: 1) PEDS SINUS PACK and 4 more
- FDAMedline Industries, LP: Medline convenience kits containing Healthmark Instrument Channel Brushes. SINUS PACK… and 1 more
- FDADeRoyal Industries Inc: REF: 81-030415 Myocardial Probe Non-Pyrogenic
- FDACardinal Health 200, LLC: Presource Convenience Kits: 1) KIT and 1 more
- FDAPhilips Ultrasound, LLC: Philips EPIQ Elite Diagnostic Ultrasound System Model # 795234
Showing the newest 150 of 1996 notices. Older ones are in the month pages and in the archive.