Intuitive Surgical, Inc.: da Vinci SP Instrument Arm Drape
Hazard (FDA): Robotic-assisted surgical system arm drapes may detach from the instrument arm due to an issue involving the drape rings located at the top of the product, which may expose a section of instrument arm, which may result…
FDAMedical devices
Intuitive Surgical, Inc.: Da Vinci ASSY
Hazard (FDA): Operative components of surgical systems potentially distributed with E-brake retainer pin, so in event of a structural column failure, the E-brake pin would prevent E-brake engagement and may result in uncontrolled…
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: Da Vinci 5 Product Name: ASSY
Hazard (FDA): Due to unintentionally activated near infrared handheld camera when attempting to turn off illumination during normal clinical workflow transitions, particularly when switching from the handheld camera to the robotic…
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: Da Vinci X and Da Vinci Xi Product Name: da Vinci X
Hazard (FDA): Due to manipulator containing screws with in the arm sub-assembly that my be susceptible to breaking.
FDAMedical devices
Intuitive Surgical, Inc.: Intuitive 8 mm SureForm 30 Gray Reloads Reference Numbers: 48230M-05 and 48230M-06
Hazard (FDA): Reloads for curved-tipped stapler may potentially produce an incomplete staple line.
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: da Vinci S and 1 more
Hazard (FDA): Due to increased in complaints regarding frayed or broken pitch cables on reusable surgical instruments
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: da Vinci S and 3 more
Hazard (FDA): Due to increased complaints for broken/frayed grip cables for reusable instruments.
FDAMedical devices
Intuitive Surgical, Inc.: Da Vinci 5 ASSY
Hazard (FDA): An error event following the release of a software version for the surgical system that can result in loss of user interface content on an external monitor or tower monitor.
FDAMedical devices
Intuitive Surgical, Inc.: da Vinci 5 Surgeon Console Viewer Display
Hazard (FDA): Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perception) but 2D maintained, or loss of both…
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: Da Vinci Product Name: da Vinci X
Hazard (FDA): Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to be used to detect Universal Surgical Manipulator insertion…
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: Ion Endoluminal System Product Name: Ion Vision Probe Bag Model/Catalog…
Hazard (FDA): Due to probe bags that may have a compromised or incomplete sterile pouch seal.
FDAMedical devices
Sterility
Intuitive Surgical, Inc.: da Vinci SP
Hazard (FDA): Access Port System tray may develop cracks potentially resulting in a sterility breach.
FDAMedical devices
Intuitive Surgical, Inc.: da Vinci 5
Hazard (FDA): Surgical system Error 23062 due to connector1) Partially damaged "Potential problem with ergonomics: Disable - Retry " or 2) Failed "Disable Ergonomics: Viewer, headrest, armrest, and pedal tray position cannot be…
FDAMedical devices
Intuitive Surgical, Inc.: Brand Name: Da Vinci 5 Product Name: ASSY
Hazard (FDA): Due to an increase in complaints concerning foot tray pedal spring failing resulting in the pedal remaining pressed
FDAMedical devices
Intuitive Surgical, Inc.: 8MM and 1 more
Hazard (FDA): Due to an increase in complaints for pitch cable failures related to forceps and small Graptor instruments
FDAMedical devices
Intuitive Surgical, Inc.: 8MM and 36 more
Hazard (FDA): Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws.
FDAMedical devices