Skip to content

2024 Ford F-150 recalls

NHTSA lists 11 safety recall campaigns for the 2024 Ford F-150. Hazard and remedy below are NHTSA’s own text.

Build snapshot. Collected , once, when this site was built. It is not a live feed.

This is the list for the model, not for your car.

A campaign often covers only some production dates or plants, and a previous owner may have had the repair done. To know whether your vehicle has an open recall, check the VIN at nhtsa.gov/recalls (opens in a new tab) .

  • NHTSA campaign 26V578000received 223,472 vehicles potentially affected

    Fuel system, gasoline: storage: tank assembly: mounting

    Hazard

    A detached tank can create a road hazard, increasing the risk of a crash. In addition, a fuel leak can cause an engine stall or increase the risk of a fire.

    What to do

    Dealers will inspect and replace the fuel tank straps, as necessary, free of charge. Owner notification letters were mailed September 21, 2026. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 26S69. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov beginning September 14, 2026.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2023-2027 F-150 vehicles. The fuel tank may be improperly secured and leak fuel, or detach from the vehicle while driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 26V104000received 4,381,878 vehicles potentially affected

    Electrical system: integrated trailer brake control; Exterior lighting: tail lights

    Hazard

    Trailer lights or brakes that do not function can reduce the driver’s ability to control the trailer and decrease the trailers visibility to other road users, increasing the risk of a crash.

    What to do

    The integrated trailer module software will be updated by a dealer, or through an over-the-air (OTA) update, free of charge. Owner notification letters were mailed March 25, 2026. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 26C10. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov beginning March 17, 2026.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2021-2026 F-150, 2022-2026 F-250 SD, F-350 SD, F-450 SD, F-550 SD, Maverick, 2024-2026 Ranger, 2023-2026 F-600 SD, 2022-2027 Lincoln Navigator, Expedition, and 2026 E-Transit vehicles. When towing a trailer, the integrated trailer module (ITRM) may lose communication with the vehicle, possibly causing a loss of brake and turn signal lights, or a loss of brake function. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, " Lamps, Reflective Devices, and Associated Equipment."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V512000received 103,174 vehicles potentially affected

    Power train: axle hubs

    Hazard

    Damaged axle hub splines can result in a vehicle rollaway when in park without the parking brake applied or cause a loss of drive power. Either of these conditions can increase the risk of a crash.

    What to do

    Dealers will replace the left and right rear axle shaft assemblies, free of charge. This is a phased recall. Ford owners will receive letters in multiple phases, beginning August 2025 through Winter 2025. Phase 1 will include 2023 F-150 model year vehicles. Phase 2 will include 2025 F-150 model year vehicles and Phase 3 will include 2024 F-150 model year vehicles. Interim owner notification letters informing owners of the safety risk were mailed August 22, 2025. Owner notification letters were mailed August 22, 2025. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 25S82. This recall expands previous NHTSA recall number 23V896.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2023-2025 F-150 vehicles equipped with the Trailer Tow Max Duty package and a 9.75-inch heavy duty axle with a 3/4 float axle design. The rear axle hub bolt may fatigue and break, which can result in damage to the axle hub splines.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V315000received 1,076,138 vehicles potentially affected

    Back over prevention: software

    Hazard

    A frozen or missing rearview camera image can reduce the driver's view behind the vehicle, increasing the risk of a crash.

    What to do

    The accessory protocol interface module (APIM) software will be updated by a dealer or through an over-the-air update, free of charge. This will be a phased campaign, with the remedy becoming available in different phases based on model and model years. Interim letters notifying owners of the safety risk were mailed on June 26, 2025. Additional letters will be mailed once the final remedy is available on each phase. Owner notification letters were sent on October 8, 2025. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 25S49.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2021-2024 Bronco, F-150, 2021-2024 Edge, 2022-2025 Escape, F-250, F-350, F-450, F-550, F-600, 2022-2024 Expedition, 2022-2025 Transit, 2021-2023 Mach-E, 2024 Ranger, Mustang, 2021-2023 Lincoln Nautilus, 2022-2024 Navigator, and 2023-2024 Corsair vehicles. A software error may cause the rearview camera image to delay, freeze, or not display when the vehicle is in reverse.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V198000received 4,356 vehicles potentially affected

    Engine and engine cooling: engine: oil/lubrication

    Hazard

    A rapid oil leak can result in an engine stall, increasing the risk of a crash. In addition, an oil leak in the presence of an ignition source such as hot engine or exhaust components, can increase the risk of a fire.

    What to do

    Dealers will inspect the engine cup plug alignment, and replace the plug if necessary, free of charge. Owner notification letters were mailed May 22, 2025. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 25S30.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024-2025 F-150, Expedition, and 2024 Lincoln Navigator vehicles equipped with 3.5L GTDI engines. The engine may have a misaligned engine cup plug, which can result in a rapid oil leak.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V164000received 269 vehicles potentially affected

    Power train: automatic transmission: fluid/lubricant: valves/valve body

    Hazard

    Unexpected vehicle movement increases the risk of a crash.

    What to do

    Dealers will replace the transmission main control valve body, free of charge. Owner notification letters were mailed April 11, 2025. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 25S19.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024-2025 F-150, Bronco, 2024 Ranger, 2025 Mustang, Explorer, and Aviator vehicles. The transmission valve body may have been machined incorrectly, which can cause reverse gear failure, or unexpected forward movement in reverse or neutral gear.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V022000received 3 vehicles potentially affected

    Steering

    Hazard

    A fractured steering gear can cause the steering to bind or lock, resulting in a loss of steering control and increasing the risk of a crash.

    What to do

    Dealers will replace the steering gear assembly, free of charge. Owner notification letters were mailed February 19, 2025. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 25S04.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024 F-150 vehicles. The steering gear assembly may have been assembled with an incorrect rack, which can cause the gears to fracture.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 24V851000received 2,490 vehicles potentially affected

    Engine and engine cooling: engine: oil/lubrication

    Hazard

    A rapid oil leak can result in an engine stall, increasing the risk of a crash. In addition, an oil leak in the presence of an ignition source such as hot engine or exhaust components, can increase the risk of a fire.

    What to do

    Dealers will inspect the engine cup plug alignment, and replace the plug if necessary, free of charge. Owner notification letters were mailed on May 23, 2024. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 24S70.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024-2025 F-150, 2024 Expedition and 2024 Lincoln Navigator vehicles equipped with a 3.5L GTDI engine. The engines may have a misaligned engine cup plug, which can result in a rapid oil leak.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 24V852000received 27,678 vehicles potentially affected

    Equipment: other: labels

    Hazard

    Without a label that shows the proper restraint usage guidelines, the occupants may have an increased risk of injury in the event of a crash.

    What to do

    Ford will mail owners the warning labels, free of charge. Owner notification letters were mailed December 19, 2024. Owners may call Ford customer service at 1-866-436-7332. Ford's number for this recall is 24C39.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2020-2025 Explorer, Lincoln Aviator, 2020-2024 Escape, Lincoln Corsair, 2018-2024 F-150, Expedition and Lincoln Navigator vehicles. The air bag warning label may be missing from the dashboard. As such, these vehicles fail to comply with the requirement Federal Motor Vehicle Safety Standard number 208, "Occupant Crash Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V486000received 4,361 vehicles potentially affected

    Visibility: windshield

    Hazard

    A windshield that detaches from a vehicle during a crash can increase the risk of injury.

    What to do

    Dealers will remove and reinstall the windshield, free of charge. Owner notification letters were mailed July 10, 2024. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 24C20.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024 F-150 vehicles. The windshield may not have been properly bonded to the vehicle, allowing it to detach during a crash. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 212, "Windshield Mounting."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V329000received 385 vehicles potentially affected

    Steering: column

    Hazard

    A loss of steering control increases the risk of a crash.

    What to do

    Dealers will replace the lower steering shaft fastener, free of charge. Owner notification letters were mailed May 22, 2024. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 24S32.
    What NHTSA says is being recalled
    Ford Motor Company (Ford) is recalling certain 2024 F-150 vehicles. The steering column lower shaft may have been secured to the steering gear assembly with an incorrect fastener, which can result in the separation of steering components and cause a loss of steering control.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

Questions about 2024 Ford F-150 recalls

How many recalls does the 2024 Ford F-150 have?

NHTSA lists 11 safety recall campaigns for the 2024 Ford F-150 as collected on November 17, 2026. Not every vehicle of the model is part of every campaign.

What is the most recent 2024 Ford F-150 recall?

Campaign 26V578000, received by NHTSA on September 9, 2026, about: fuel system, gasoline: storage: tank assembly: mounting. NHTSA states: “A detached tank can create a road hazard, increasing the risk of a crash. In addition, a fuel leak can cause an engine stall or increase the risk of a fire.”

Is there a “do not drive” or “park outside” advisory for the 2024 Ford F-150?

None of the campaigns collected on November 17, 2026 carries one.

How do I check my own Ford F-150?

Enter the 17-character VIN at nhtsa.gov/recalls. That is the only way to know whether your vehicle is included in a campaign and whether the repair was already done.

Other Ford pages

Keep checking