NHTSA lists 14 safety recall campaigns for the 2023 Jeep Wrangler, at least one with a “do not drive” or “park outside” advisory. Hazard and remedy below are NHTSA’s own text.

Build snapshot. Collected , once, when this site was built. It is not a live feed.

This is the list for the model, not for your car.

A campaign often covers only some production dates or plants, and a previous owner may have had the repair done. To know whether your vehicle has an open recall, check the VIN at nhtsa.gov/recalls (opens in a new tab) .

  • NHTSA campaign 26V363000received 1,076,999 vehicles potentially affected

    Steering: hydraulic power assist: pump

    NHTSA flagsNHTSA: park outside

    Hazard

    A vehicle fire increases the risk of injury.

    What to do

    Owners are advised to park outside and away from structures, until their vehicle is repaired. Dealers will inspect and replace the wiring and electric hydraulic power steering pump, as necessary, free of charge. Owner notification letters are expected to be mailed July 9, 2026. Owners may contact FCA US LLC customer service at 1-800-853-1403. FCA US LLC's number for this recall is 21D. The Vehicle Identification Numbers (VINs) involved in this recall will become searchable on NHTSA.gov on June 11, 2026.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2025 Jeep Wrangler, Wrangler 4XE, and Jeep Gladiator vehicles. The electric hydraulic power steering pump wiring may overheat and cause a vehicle fire, even when the vehicle is parked with the ignition in the "Off" position.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V741000received 320,068 vehicles potentially affected

    Electrical system: propulsion system: traction battery

    NHTSA flagsNHTSA: park outside

    Hazard

    A vehicle fire can increase the risk of injury.

    What to do

    Owners are advised to park outside and away from structures and not to charge their vehicles until the remedy is completed. Dealers will update the high voltage battery software, and replace the high voltage battery, as necessary, free of charge. Some owner notification letters were mailed beginning December 17, 2025. The remaining owner notification letters will be mailed at a later date. Owners may contact Chrysler customer service at 800-853-1403. Chrysler's number for this recall is 68C. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov beginning November 6, 2025. Vehicles that were previously recalled for the same issue under NHTSA Recalls 24V720 and 23V787 will need to have the new remedy performed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2020-2025 Jeep Wrangler 4Xe and 2022-2026 Grand Cherokee 4Xe vehicles. The high voltage battery may fail internally and lead to a vehicle fire while parked or driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 24V676000received 46 vehicles potentially affected

    Back over prevention: sensing system: camera; Exterior lighting: brake lights

    Hazard

    A rearview camera image that does not display decreases the driver's visibility, increasing the risk of a crash. Additionally, a center brake light that fails to illuminate can fail to indicate to other drivers that the vehicle is slowing down, increasing the risk of a crash.

    What to do

    Dealers replaced the harness for the center brake light and rearview camera and/or the spare tire carrier/harness assembly, as necessary, free of charge. All vehicles were repaired by January 15, 2024. Owner notification letters were mailed September 26, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 77B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2018-2024 Jeep Wrangler vehicles. The wiring harness for the rearview camera and the center brake light may short circuit, which can disable the rearview camera image and center brake light. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard numbers 111, "Rear Visibility" and 108, "Lamps, Reflective Devices, and Associated Equipment."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V652000received 32,863 vehicles potentially affected

    Electrical system: instrument cluster/panel

    Hazard

    An instrument panel that fails to display critical safety information, such as the speedometer or warning lights, can increase the risk of a crash.

    What to do

    Dealers will replace the instrument panel cluster, free of charge. Owner notification letters were mailed between October 3, 2024, and January 23, 2025. Owners may contact FCA customer service at 1-800-853-1403. FCA's number for this recall is 30B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2020-2024 Jeep Gladiator and 2018-2024 Jeep Wrangler vehicles. The instrument panel cluster may experience an internal short circuit and fail. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 101, "Controls and Displays."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V199000received 38,164 vehicles potentially affected

    Air bags: frontal: driver clockspring/spiral cassette; Steering: column

    Hazard

    An air bag that does not deploy in a crash can increase the risk of injury.

    What to do

    Dealers will inspect and replace the steering column control module, as necessary free of charge. Some owner notification letters were mailed April 11, 2024 through June 20, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's numbers for this recall are 14B, 33B, 34B, 35B, 36B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) (Stellantis) is recalling certain 2023-2024 Ram 1500, Jeep Wrangler, Jeep Wagoneer, Jeep Grand Wagoneer, Chrysler Pacifica, Ram 3500, Ram 3500 cab chassis, Ram 2500, Ram 4500 cab chassis, Ram 5500 cab chassis, 2023 Jeep Gladiator, Jeep Grand Cherokee, Jeep Grand Cherokee L, Ram 3500 Cab Chassis with a GVWR less than 10,000 lbs., and Chrysler Voyager vehicles. The steering column control module may not be welded properly, which can prevent the driver's air bag from deploying in a crash. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 208, "Occupant Crash Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V111000received 199,143 vehicles potentially affected

    Visibility: defroster/defogger/hvac system

    Hazard

    An inoperative windshield defrosting and defogging system may decrease the driver's visibility, increasing the risk of a crash.

    What to do

    Dealers will update the HCP software, free of charge. Owner notification letters were mailed February 29, 2024. Owners may contact Chrysler customer service at 1-800-853-1403. Chrysler's number for this recall is 04B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2024 Jeep Wrangler and 2022-2024 Jeep Grand Cherokee vehicles. A hybrid control processor (HCP) software error may cause the defrosting and defogging system to be inoperative. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 103, "Windshield Defrosting and Defogging Systems."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V787000received 32,125 vehicles potentially affected

    Electrical system: propulsion system: traction battery

    NHTSA flagsNHTSA: park outside

    Hazard

    A vehicle fire while parked or driving can increase the risk of injury.

    What to do

    Owners are advised not to recharge their vehicles, and to park outside and away from structures, until they are repaired. Dealers will update the high voltage battery pack software and replace the battery pack assembly if necessary, free of charge. Owner notification letters were mailed March 7, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 89A. This recall is superseded by NHTSA Recall 24V-720.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Wrangler Plug-In Hybrid Electric (PHEV) vehicles. The high voltage battery may fail internally and lead to a vehicle fire while parked or driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V641000received 6,298 vehicles potentially affected

    Power train: manual transmission

    Hazard

    A disabled rearview image can decrease the driver's visibility of the rear view, and disabled reverse lights may not alert others that the vehicle is reversing, increasing the risk of injury or crash.

    What to do

    Dealers will replace the gear position sensor, free of charge. Owner notification letters were mailed November 16, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 92A.
    What NHTSA says is being recalled
    Chrysler (FCA US), LLC is recalling certain 2022-2023 Jeep Wrangler and Gladiator vehicles equipped with a manual transmission. The rearview camera may fail to display the rearview image and the reverse lights may not illuminate when the vehicle is placed in reverse. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard numbers 111, "Rear Visibility" and 108, "Lamps, Reflective Devices, and Associated Equipment."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V565000received 16 vehicles potentially affected

    Exterior lighting: brake lights

    Hazard

    A brake light that is obstructed may not be visible to other drivers to indicate the intention to slow or stop, increasing the risk of a crash.

    What to do

    Dealers will replace the spare tire carrier assembly, free of charge. Owner notification letters were mailed September 28, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 84A.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023 Jeep Wrangler vehicles. The spare tire may obstruct the view of the center high-mount brake light. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V303000received 2,564 vehicles potentially affected

    Electrical system: propulsion system: traction battery

    Hazard

    Excessive heat may cause the fuse to fail and result in a loss of drive power, increasing the risk of a crash.

    What to do

    Dealers will inspect and replace the HV battery fuse, as necessary. Dealers will also inspect the battery assembly for damage and replace it, if necessary. Repairs will be performed free of charge. Owner notification letters were mailed May 23, 2023. Owners may contact Chrysler customer service at 1-800-853-1403. Chrysler's number for this recall is 53A. This recall is an expansion of previous recall 22V-768.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Wrangler Plug-In Hybrid Electric vehicles (PHEV). The high voltage (HV) battery pack assembly was built with incorrect fasteners to secure the 200-amp fuse, which can generate excessive heat.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V263000received 45,832 vehicles potentially affected

    Fuel system, diesel: delivery: fuel pump

    Hazard

    Fuel pump failure can result in an engine stall, increasing the risk of a crash.

    What to do

    Dealers will replace the HPFP and replace additional fuel system components, as necessary, free of charge. Owner notification letters were mailed October 17, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 01A.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Wrangler, Gladiator, and 2022-2023 Ram 1500 vehicles equipped with a 3.0L diesel engine. The high pressure fuel pump (HPFP) may fail.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V116000received 69,201 vehicles potentially affected

    Power train: clutch assembly

    Hazard

    Overheated clutch components may increase the risk of a fire. Additionally, damage to other nearby components can result in debris falling onto the road or a loss of drive, increasing the risk of a crash.

    What to do

    Dealers will replace the clutch assembly and update the software, free of charge. Owner notification letters were mailed from November 16, 2023 through July 25, 2024. Owners may contact (FCA US, LLC) customer service at 1-800-853-1403. FCA US LLC's number for this recall is 19A. This recall expands and replaces previous recall 21V-028. Vehicles previously repaired under recall 21V-028 will need to have the new remedy completed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2018-2023 Jeep Wrangler, and 2020-2023 Jeep Gladiator vehicles equipped with manual transmissions. The clutch pressure plate may overheat and fracture.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 22V865000received 62,909 vehicles potentially affected

    Engine

    Hazard

    An engine shutdown can cause a loss of drive power, increasing the risk of a crash.

    What to do

    There is more than one involved component and calibration software. Updating the calibration software in the Transmission Control Module, Hybrid Control Processor and Auxiliary Hybrid Control Processor that changes fail safe from shut down to limp home. Dealers will update the transmission control module software, Hybrid Control Processor and Auxiliary Hybrid Control Processor, free of charge. Owner notification letters were mailed December 22, 2022. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall ZB7.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Wrangler 4xe vehicles equipped with 2.0L Plug-In Hybrid Electric Vehicle engines. A loss of communication may cause an engine shutdown.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 22V768000received 13,722 vehicles potentially affected

    Electrical system: propulsion system: traction battery

    Hazard

    Excessive heat may cause the fuse to fail and result in a loss of drive power, increasing the risk of a crash.

    What to do

    Dealers will inspect and replace the HV battery fuse, as necessary. Dealers will also inspect the battery assembly for damage and replace it, if necessary. Repairs will be performed free of charge. Owner notification letters were mailed December 8, 2022. Owners may contact Chrysler customer service at 1-800-853-1403. Chrysler's number for this recall is Z71.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Wrangler Plug-In Hybrid Electric (PHEV) vehicles. The high voltage (HV) battery pack assembly was built with incorrect fasteners to secure the 200-amp fuse, which can generate excessive heat.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

Questions about 2023 Jeep Wrangler recalls

How many recalls does the 2023 Jeep Wrangler have?

NHTSA lists 14 safety recall campaigns for the 2023 Jeep Wrangler as collected on November 17, 2026. Not every vehicle of the model is part of every campaign.

What is the most recent 2023 Jeep Wrangler recall?

Campaign 26V363000, received by NHTSA on June 4, 2026, about: steering: hydraulic power assist: pump. NHTSA states: “A vehicle fire increases the risk of injury.”

Is there a “do not drive” or “park outside” advisory for the 2023 Jeep Wrangler?

Yes. NHTSA attached such an advisory to campaigns 26V363000, 25V741000, 23V787000. See the campaign on this page and check your VIN.

How do I check my own Jeep Wrangler?

Enter the 17-character VIN at nhtsa.gov/recalls. That is the only way to know whether your vehicle is included in a campaign and whether the repair was already done.

Other Jeep pages

Keep checking