A campaign often covers only some production dates or plants, and a previous owner may have had the repair done. To know whether your vehicle has an open recall, check the VIN at nhtsa.gov/recalls (opens in a new tab) .

  • NHTSA campaign 26V562000received 328,381 vehicles potentially affected

    Suspension: rear: springs: coil springs

    Hazard

    Rear coil springs that detach from the vehicle while driving increase the risk of a crash.

    What to do

    Dealers will replace the rear coil spring lower isolators, free of charge. Interim notification letters, notifying owners of the safety risk, were mailed September 29, 2026. Additional letters will be sent once the final remedy is available. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 89D. Vehicle Identification Numbers (VINs) involved in this recall will become searchable on NHTSA.gov on September 9, 2026. This recall replaces NHTSA recall numbers 26V051 and 23V413. Vehicles already repaired under the previous recalls will need to have the new remedy completed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Grand Cherokee L, 2022-2023 Jeep Grand Cherokee, and Jeep Grand Cherokee 4XE vehicles. The rear coil springs may be incorrectly installed and detach from the vehicle while driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 26V413000received 7 vehicles potentially affected

    Power train: automatic transmission: gear position indication (prndl)

    Hazard

    A missing gear selection indicator may lead to unintended vehicle movement or a vehicle rollaway, increasing the risk of a crash.

    What to do

    Dealers will update the shifter module software, free of charge. Owner notification letters were mailed August 20, 2026. Owners may contact Chrysler customer service at 800-853-1403. Chrysler's number for this recall is 30D. Vehicle Identification Numbers (VINs) involved in this recall will become searchable on NHTSA.gov beginning July 9, 2026.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2024 Jeep Grand Cherokee, 2023 Jeep Wagoneer, 2024 Jeep Grand Cherokee L, and Jeep Wagoneer L vehicles. A software error may cause the transmission gear selection indicator not to display. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 102, "Transmission shift lever sequence, starter interlock, and transmission braking effect."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 26V328000received 419,035 vehicles potentially affected

    Air bags: air bag/restraint control module: software

    Hazard

    Delayed air bag deployment during a crash increases the risk of injury.

    What to do

    Dealers will update the occupant restraint controller module software, free of charge. Some owner notification letters are expected to be mailed June 18, 2026. Owners may contact Chrysler customer service at 800-853-1403. Chrysler's number for this recall is 01D. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov on May 28, 2026.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2026 Jeep Grand Cherokee and 2023-2025 Jeep Grand Cherokee L vehicles. A software error in the occupant restraint controller module may cause the delayed deployment of the side air bags during a crash. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 214, "Side Impact Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 26V051000received 80,620 vehicles potentially affected

    Suspension: rear: springs: coil springs

    Hazard

    Rear coil springs that detach from the vehicle while driving increase the risk of a crash.

    What to do

    Dealers will inspect and repair the rear coil spring assembly, as necessary, free of charge. Interim notification letters, notifying owners of the safety risk, were mailed February 12, 2026. Additional letters will be sent once the final remedy is available, anticipated in March 2026. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 20D. Vehicle Identification Numbers (VINs) involved in this recall became searchable on NHTSA.gov on January 30, 2026. This recall replaces NHTSA recall number 23V413. Vehicles already repaired under the previous recall will need to have the new remedy completed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Grand Cherokee L and 2022-2023 Jeep Grand Cherokee vehicles. The rear coil springs may be incorrectly installed and detach from the vehicle while driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V741000received 320,068 vehicles potentially affected

    Electrical system: propulsion system: traction battery

    NHTSA flagsNHTSA: park outside

    Hazard

    A vehicle fire can increase the risk of injury.

    What to do

    Owners are advised to park outside and away from structures and not to charge their vehicles until the remedy is completed. Dealers will update the high voltage battery software, and replace the high voltage battery, as necessary, free of charge. Some owner notification letters were mailed beginning December 17, 2025. The remaining owner notification letters will be mailed at a later date. Owners may contact Chrysler customer service at 800-853-1403. Chrysler's number for this recall is 68C. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov beginning November 6, 2025. Vehicles that were previously recalled for the same issue under NHTSA Recalls 24V720 and 23V787 will need to have the new remedy performed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2020-2025 Jeep Wrangler 4Xe and 2022-2026 Grand Cherokee 4Xe vehicles. The high voltage battery may fail internally and lead to a vehicle fire while parked or driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V576000received 91,787 vehicles potentially affected

    Electrical system: propulsion system

    Hazard

    A loss of drive power increases the risk of a crash.

    What to do

    Dealers will update the hybrid control processer software, free of charge. Owner notification letters were mailed October 14, 2025. Owners may contact Chrysler customer service at 800-853-1403. Chrysler's number for this recall is 73C. Vehicle Identification Numbers (VINs) involved in this recall will be searchable on NHTSA.gov beginning September 11, 2025.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2026 Jeep Grand Cherokee Plug-In Hybrid Electric (PHEV) vehicles. A software error within the hybrid control processor may result in a loss of drive power.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V472000received 121,398 vehicles potentially affected

    Seats: mid/rear assembly: head restraint

    Hazard

    Head restraints that do not lock can result in an increased risk of injury to seat occupants during a crash.

    What to do

    Dealers will inspect and replace both second-row seat head restraints, as necessary, free of charge. Owner notification letters were mailed September 5, 2025. Owners may contact FCA US LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 20C.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023-2024 Jeep Grand Cherokee and Jeep Grand Cherokee L vehicles. The second-row seat head restraints may not lock in the upright position. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 202, "Head Restraints."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 25V430000received 1,689 vehicles potentially affected

    Visibility: defroster/defogger/hvac system: fan/motor

    Hazard

    An inoperative windshield defrosting and defogging system may decrease the driver's visibility, increasing the risk of a crash.

    What to do

    Dealers will inspect and replace the blower motor, as necessary free of charge. Owner notification letters were mailed July 8, 2025. Owners may contact Chrysler customer service at 1-800-853-1403. Chrysler's number for this recall is 49C.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023 Jeep Grand Cherokee and Jeep Grand Cherokee L vehicles. The blower motor may fail, which can cause the defrosting and defogging system to be inoperative. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 103, "Windshield Defrosting and Defogging Systems."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 24V897000received 14 vehicles potentially affected

    Air bags: side/window

    Hazard

    An air bag that does not deploy during a crash increases the risk of injury.

    What to do

    Dealers secured the connector, free of charge. All affected vehicles have been remedied. Owner notification letters were mailed December 17, 2024. Owners may contact FCA customer service at 1-800-853-1403. FCA's number for this recall is B3B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2024 Jeep Grand Cherokee and 2021-2024 Jeep Grand Cherokee L vehicles. An improperly secured connector for the front seat side air bags (SAB) may prevent the air bags from deploying. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 214, "Side Impact Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 24V436000received 1,033,433 vehicles potentially affected

    Back over prevention: sensing system: camera

    Hazard

    A rearview camera image that does not display decreases the driver's visibility, increasing the risk of a crash.

    What to do

    Dealers will update the radio software or the software will be OTA, "Over-The-Air," free of charge. Owner notification letters were mailed beginning July 9, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's numbers for this recall are 66B and 79B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2022 Dodge Durango, 2021-2023 Chrysler Pacifica, Jeep Grand Cherokee L, 2022 Ram 1500, 2500, 3500, Chrysler Voyager, 2022-2023 Jeep Compass, Grand Cherokee, Wagoneer, Grand Wagoneer, and Ram Promaster vehicles. The radio software may prevent the rearview image from displaying. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V434000received 53 vehicles potentially affected

    Seat belts: critical fasteners

    Hazard

    An improperly secured seat belt buckle may not properly restrain occupants during a crash, increasing the risk of injury.

    What to do

    Dealers will inspect and tighten the second-row seat buckle bolt as necessary, free of charge. Owner notification letters were mailed July 9, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 70B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023 Jeep Grand Cherokee vehicles. A bolt for the second-row seat belt buckle may not be tightened properly. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 210, "Seat Belt Assembly Anchorages."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V291000received 2 vehicles potentially affected

    Back over prevention: sensing system: camera

    Hazard

    A rearview camera image that does not display decreases the driver's visibility, increasing the risk of injury or crash.

    What to do

    Dealers will secure the display screen module connections, free of charge. All vehicles have been remedied. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 44B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023 Jeep Grand Cherokee and Grand Cherokee L vehicles. Improperly fastened screen module connections may prevent the rearview camera image from displaying. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V289000received 8 vehicles potentially affected

    Back over prevention: sensing system: camera

    Hazard

    A rearview camera image that does not display decreases the driver's visibility, increasing the risk of injury or crash.

    What to do

    Dealers will secure the coaxial cable connection, free of charge. All affected vehicles have been remedied. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 40B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Grand Cherokee and 2023-2024 Jeep Grand Cherokee L vehicles. An improperly connected coaxial cable may prevent the rearview camera image from displaying. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V199000received 38,164 vehicles potentially affected

    Air bags: frontal: driver clockspring/spiral cassette; Steering: column

    Hazard

    An air bag that does not deploy in a crash can increase the risk of injury.

    What to do

    Dealers will inspect and replace the steering column control module, as necessary free of charge. Some owner notification letters were mailed April 11, 2024 through June 20, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's numbers for this recall are 14B, 33B, 34B, 35B, 36B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) (Stellantis) is recalling certain 2023-2024 Ram 1500, Jeep Wrangler, Jeep Wagoneer, Jeep Grand Wagoneer, Chrysler Pacifica, Ram 3500, Ram 3500 cab chassis, Ram 2500, Ram 4500 cab chassis, Ram 5500 cab chassis, 2023 Jeep Gladiator, Jeep Grand Cherokee, Jeep Grand Cherokee L, Ram 3500 Cab Chassis with a GVWR less than 10,000 lbs., and Chrysler Voyager vehicles. The steering column control module may not be welded properly, which can prevent the driver's air bag from deploying in a crash. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 208, "Occupant Crash Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V132000received 338,238 vehicles potentially affected

    Suspension: front: control arm: upper ball joint; Steering: linkages: knuckle: spindle: arm

    Hazard

    A loss of vehicle control increases the risk of a crash.

    What to do

    Dealers will replace the upper control arm pinch bolts, free of charge. Owner notification letters were mailed April 2, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA's number for this recall is 10B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2023 Jeep Grand Cherokee L and 2022-2023 Jeep Grand Cherokee vehicles. The upper control arm ball joint and steering knuckle may separate and cause the wheel to fall outward, resulting in a loss of vehicle control.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V130000received 9,433 vehicles potentially affected

    Exterior lighting: headlights; Electrical system: body control module: software

    Hazard

    High beam headlights that do not activate as intended can reduce visibility, increasing the risk of a crash.

    What to do

    Dealers will reconfigure the vehicle high beam parameters, free of charge. Owner notification letters were mailed March 7, 2024. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA's number for this recall is 12B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2023-2024 Jeep Grand Cherokee and Jeep Grand Cherokee L vehicles. When the master headlight switch is set to the AUTO position, the driver may be unable to quickly activate the high beams. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 24V111000received 199,143 vehicles potentially affected

    Visibility: defroster/defogger/hvac system

    Hazard

    An inoperative windshield defrosting and defogging system may decrease the driver's visibility, increasing the risk of a crash.

    What to do

    Dealers will update the HCP software, free of charge. Owner notification letters were mailed February 29, 2024. Owners may contact Chrysler customer service at 1-800-853-1403. Chrysler's number for this recall is 04B.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2021-2024 Jeep Wrangler and 2022-2024 Jeep Grand Cherokee vehicles. A hybrid control processor (HCP) software error may cause the defrosting and defogging system to be inoperative. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 103, "Windshield Defrosting and Defogging Systems."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V577000received 162,713 vehicles potentially affected

    Back over prevention: display function

    Hazard

    A rearview image that does not display while in reverse decreases the driver's visibility of the rear view, increasing the risk of injury or crash.

    What to do

    Dealers will update the Central Vision Park Assist Module software, free of charge. Owner notification letters were mailed August 31, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 56A.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Grand Cherokee, 2021-2023 Jeep Grand Cherokee L, and 2022-2024 Jeep Wagoneer and Grand Wagoneer vehicles. The Central Vision Park Assist module (CVPAM) software may prevent the rearview image from displaying when the vehicle is placed in reverse. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V413000received 305,282 vehicles potentially affected

    Suspension: rear: springs: coil springs

    Hazard

    Rear coil springs that detach from the vehicle while driving increases the risk of a crash.

    What to do

    Dealers will inspect and if necessary, repair the rear coil spring assemblies, free of charge. Owner notification letters were mailed June 29, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 64A. This recall is replaced by NHTSA recall 26V051. All vehicles will need to have the new recall remedy performed.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Grand Cherokee and 2021-2023 Jeep Grand Cherokee L vehicles. The rear coil springs may have been incorrectly installed and detach from the vehicle while driving.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V352000received 89,372 vehicles potentially affected

    Steering: column

    Hazard

    A loss of steering control increases the risk of a crash.

    What to do

    Dealers will inspect and, if necessary, replace the intermediate shaft and assembly parts, free of charge. Owner notification letters were mailed June 6, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 58A.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Grand Cherokee and 2021-2023 Jeep Grand Cherokee L vehicles. An incorrectly assembled steering column intermediate shaft may disconnect from the u-joint, and result in a loss of steering control.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 23V336000received 17,108 vehicles potentially affected

    Equipment: other: labels

    Hazard

    Without a label that shows the proper restraint usage guidelines, the occupants may have an increased risk of injury in the event of a crash.

    What to do

    FCA US, LLC will mail owners the warning label information, free of charge. Dealers will inspect unsold vehicles and install the required label, as necessary, free of charge. Owner notification letters were mailed May 25, 2023. Owners may contact FCA US, LLC customer service at 1-800-853-1403. FCA US, LLC's number for this recall is 52A.
    What NHTSA says is being recalled
    Chrysler (FCA US, LLC) is recalling certain 2022-2023 Jeep Grand Cherokee L and Grand Cherokee vehicles. The air bag warning label may be missing from the dashboard. As such, these vehicles fail to comply with the requirement Federal Motor Vehicle Safety Standard number 208, "Occupant Crash Protection."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

Questions about 2023 Jeep Grand Cherokee recalls

How many recalls does the 2023 Jeep Grand Cherokee have?

NHTSA lists 21 safety recall campaigns for the 2023 Jeep Grand Cherokee as collected on November 17, 2026. Not every vehicle of the model is part of every campaign.

What is the most recent 2023 Jeep Grand Cherokee recall?

Campaign 26V562000, received by NHTSA on September 1, 2026, about: suspension: rear: springs: coil springs. NHTSA states: “Rear coil springs that detach from the vehicle while driving increase the risk of a crash.”

Is there a “do not drive” or “park outside” advisory for the 2023 Jeep Grand Cherokee?

Yes. NHTSA attached such an advisory to campaign 25V741000. See the campaign on this page and check your VIN.

How do I check my own Jeep Grand Cherokee?

Enter the 17-character VIN at nhtsa.gov/recalls. That is the only way to know whether your vehicle is included in a campaign and whether the repair was already done.

Other Jeep pages

Keep checking