  • NHTSA campaign 25V437000received 443,899 vehicles potentially affected

    Engine and engine cooling: engine: hard parts internal/mechanical

    Hazard

    Engine failure increases the risk of a crash. A bearing failure may cause a breach in the engine block, allowing hot oil to be discharged, increasing the risk of an engine fire.

    What to do

    Dealers will reprogram the engine control module (ECM) software, free of charge. Owner letters were mailed April 8, 2026. Owners may contact Nissan's customer service at 800-647-7261 or Infiniti's customer service at 1-800-662-6200. Nissan's numbers for this recall are R25A8/A9 and R25B1/B2.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021-2024 Rogue, 2019-2020 Altima, 2019-2022 Infiniti QX50, and 2022 Infiniti QX55 vehicles equipped with 3-cylinder 1.5L or 4-cylinder 2.0L variable compression turbo (VC-Turbo) engines. The engine bearings may have manufacturing defects that can lead to engine failure.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)Page of this campaign

  • NHTSA campaign 23V791000received 2 vehicles potentially affected

    Service brakes, hydraulic: foundation components: disc: caliper

    Hazard

    A loss of brake fluid may reduce braking performance, increasing the risk of crash.

    What to do

    Dealers will replace the left and right rear brake calipers, free of charge. Owner notification letters were mailed January 12, 2024. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is PC933. The two vehicles that were previously inspected under recall 21V-286 and did not receive a brake caliper replacement will need to have the new remedy completed.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Rogue vehicles. The left and/or right rear brake caliper assemblies may be missing an internal bushing, allowing the O-ring seal to move and brake fluid to leak.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 22V772000received 27,388 vehicles potentially affected

    Back over prevention: display function

    Hazard

    An inoperative rearview camera display reduces the driver's rear visibility, increasing the risk of a crash.

    What to do

    The IVI software will be updated by a dealer, or through an over-the-air (OTA) update, free of charge. Owner notification letters are expected to be mailed November 18, 2022. Owners may contact Nissan's customer service at 1-800-867-7669. Nissan's numbers for this recall are R22B8, R22C1, and PC923/25.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2022 Titan, Titan XD, Frontier, and 2021-2022 Rogue vehicles. The in-vehicle infotainment (IVI) system may continuously reboot when the vehicle is restarted, which can result in an inoperative rearview display. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 22V666000received 8,391 vehicles potentially affected

    Seat belts: rear/other: buckle assembly

    Hazard

    Seat belts that do not retract properly may be difficult to operate, preventing their usage, which can increase the risk of injury in a crash.

    What to do

    Dealers will inspect and replace the rear seat belts, as necessary, free of charge. Owner notification letters are expected to be mailed October 27, 2023. Owners may contact Nissan's customer service at 1-800-867-7669. Nissan's number for this recall is PC915.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021-2022 Rogue vehicles. The rear seat belts for the left-hand and right-hand rear seats may not retract properly. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard numbers 208, "Occupant Crash Protection," and 209, "Seatbelt Assemblies."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 22V527000received 10,477 vehicles potentially affected

    Equipment: electrical: infotainment: software; Back over prevention: sensing system: camera

    Hazard

    An inoperative rearview camera display reduces the driver's rear visibility, increasing the risk of a crash.

    What to do

    The Infotainment system software will be updated by a dealer, or through an over-the-air (OTA) update, free of charge. Owner notification letters are expected to be mailed July 29, 2022. Owners may contact Nissan's customer service at 1-800-867-7669. Nissan's number for this recall is R22A5 PC901 PC902.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021-2022 Rogue, 2022 Frontier, Pathfinder, and Titan rental vehicles. When the Sirius XM subscription is set to "Not Subscribed," it may cause the infotainment head unit to reboot, resulting in an inoperative rearview camera. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 111, "Rear Visibility."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 21V957000received 24,793 vehicles potentially affected

    Fuel system, gasoline: delivery: fuel pump

    Hazard

    Fuel pump failure may cause an engine stall, increasing the risk of a crash.

    What to do

    Dealers will replace the fuel pump assembly, free of charge. Owner notification letters were mailed January 27, 2022. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is R21B8.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Rogue vehicles. Abnormal wear inside the fuel pump may cause it to overheat and fail.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 21V474000received 47,098 vehicles potentially affected

    Seats: mid/rear assembly; Child seat: vehicle tether anchor

    Hazard

    An insecurely anchored child seat can move during a sudden stop or crash, increasing the risk of injury.

    What to do

    Dealers will inspect and replace the rear seatbacks as necessary, free of charge. Owner notification letters were mailed July 30, 2021. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is PC812.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Rogue vehicles. The second-row upper tether wires may have been improperly welded to the seatback frame, preventing a child seat from being securely anchored. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 225, "Child Restraint Anchorage Systems."

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 21V286000received 14,054 vehicles potentially affected

    Service brakes, hydraulic: foundation components: disc: caliper

    Hazard

    A loss of brake fluid may reduce braking performance, increasing the risk of crash.

    What to do

    Dealers will inspect and replace the left and/or right rear brake calipers, as necessary, free of charge. Owner notification letters were mailed June 10, 2021. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is PC804.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Rogue vehicles. The rear left and/or right brake caliper assemblies may be missing an internal bushing, allowing the O-ring seal to move and brake fluid to leak.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 21V186000received 21 vehicles potentially affected

    Wheels: lugs/nuts/bolts/studs

    Hazard

    The wheel vibration may break the wheel studs and cause the wheel assembly to separate from the vehicle, increasing the risk of a crash.

    What to do

    Nissan will notify owners, and dealers will inspect the wheel nuts and replace any incorrect ones, free of charge. The recall began May 4, 2021. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is PC799.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Nissan Rogue vehicles. The incorrect wheel nuts may have been installed, and may loosen causing wheel vibration.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

  • NHTSA campaign 21V068000received 2,150 vehicles potentially affected

    Fuel system, gasoline: delivery: hoses, lines/piping, and fittings; Fuel system, gasoline: storage: tank assembly

    Hazard

    An improperly secured fuel hose may leak, increasing the risk of a fire. The fuel hose may also disconnect completely, causing the engine to stall and increasing the risk of a crash.

    What to do

    Nissan will notify owners, and dealers will inspect and, as necessary, reposition and secure the fuel hose and lock ring, free of charge. The recall began March 16, 2021. Owners may contact Nissan customer service at 1-800-867-7669. Nissan's number for this recall is PC791.
    What NHTSA says is being recalled
    Nissan North America, Inc. (Nissan) is recalling certain 2021 Nissan Rogue vehicles. The fuel hose may not be secured in the proper position and the fuel tank lock ring may not be fully seated.

    Text from NHTSA, unedited.Official NHTSA page (opens in a new tab)

Questions about 2021 Nissan Rogue recalls

How many recalls does the 2021 Nissan Rogue have?

NHTSA lists 10 safety recall campaigns for the 2021 Nissan Rogue as collected on November 17, 2026. Not every vehicle of the model is part of every campaign.

What is the most recent 2021 Nissan Rogue recall?

Campaign 25V437000, received by NHTSA on June 27, 2025, about: engine and engine cooling: engine: hard parts internal/mechanical. NHTSA states: “Engine failure increases the risk of a crash. A bearing failure may cause a breach in the engine block, allowing hot oil to be discharged, increasing the risk of an engine fire.”

Is there a “do not drive” or “park outside” advisory for the 2021 Nissan Rogue?

None of the campaigns collected on November 17, 2026 carries one.

How do I check my own Nissan Rogue?

Enter the 17-character VIN at nhtsa.gov/recalls. That is the only way to know whether your vehicle is included in a campaign and whether the repair was already done.