Why it was recalled

Torque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision, procedural delays, requirement for alternate head fixation methods, and risk of patient injury.
Text from FDA, unedited.

FDA classification: Class II. What the FDA’s classes mean (opens in a new tab)

The recalled product

Codes in the record. Click one to copy it.

122 more codes are in the record below.

  • Brand Name: HFD100 Product Name: Head Fixation Device HFD100 Model/Catalog Number: 119695-000, 119629-000, 119630-000, 113803-000, 113803-600, 113802-000, 113802-600 Software Version: Not Applicable Product Description: The HFD100 Head Fixation Device provides rigid skeletal fixation within the optimal imaging envelope while introducing minimal artifacts in the acquired images. There are two different assemblies for the HFD100. The standard HFD100 is equipped with a table adapter for use with either the operating room table or the angiography table. For sites with a Hill-Rom TruSystem 7500 Hybrid Neuro MR Operating Table (ORT400), the HFD100 has a split block clamp assembly (Trumpf Mount Clamp Assembly) which connects directly to the table back section. The HFD100 system is also comprised of the linkage components to mount the skull clamp to the table adapter, and the 3-pin skull clamp. The linkage system is used to position the skull clamp in the necessary position, without colliding with the magnet bore. Component: Not a component.

    Lot or code
    Affected UDI-DI: 00857534006011 00857534006592 00857534006608 00857534006615 Affected serial numbers: 10006206 10005998 10003999 10004026 10003796 10003811 10006629 10006630 10007514 10007515 10002486 10003048 10004215 10004216 10003794 10004231 10012064 10012310 10012311 10010990 10011142 10007914 10007971 10002391 10002969 10009132 10010058 10011570 10005134 10005711 10009569 10009878 10010057 10003903 10003906 10003546 10006187 10012838 10010639 10010666 10011925 10006692 10007246 10011463 10005092 10007237 10007509 10008416 10003407 10003793 10004195 10004975 10004993 10005136 10010381 10007906 10013179 10007510 10007511 10007245 10004449 10004961 10005849 10005851 10010747 10006730 10011187 10011307 10009593 10010003 10008073 10008354 10011546 10011571 10006207 10012127 10006631 10007777 10006411 10004466 10005445 10011645 10009015 10004291 10003985 10003987 10006204 10006205 10007235 10007236 10006412 10004775 10004323 10004942 10003936 10003937 10007130 10002695 10007126 10007128 10009228 10009210 10009583 10005480 10005481 10012839 10008645 10008670 10006693 10006694 10004317 10002403 10004673 10004671 10010572 10006212 10006203 10002968 10002715 10011186 10011265 10010059
    FDA recall number
    Z-1034-2026
    Quantity
    122

Distribution (FDA): Worldwide distribution - US Nationwide and the countries of Canada, Sweden, Switzerland, Japan, Australia, Qatar, and China.

Source

Issued by
U.S. Food and Drug Administration
Firm
IMRIS Imaging Inc
Title
Composed by Recalls Watch from fields of the record; FDA records have no title.

Check all notices that name this firm in the directory of recalls by brand and manufacturer. This notice is in these lists: Firm: IMRIS Imaging Inc, Month: January 2026, Week 2026-W03. Browse more medical devices recalls, or check another notice by its number in the recall number lookup.

About this recall

What is the hazard?

FDA states: “Torque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision, procedural delays, requirement for alternate head fixation methods, and risk of patient injury.”

What should I do if I have this product?

FDA’s record gives no instruction for consumers. The official report is linked on this page.

How do I know if my product is included?

Compare the lot or code printed on your product with the codes FDA lists on this notice, product by product.

How does the code check on this page work?

You type the lot, batch, date code, model number or UPC from your package and the page compares it, in your browser, with the codes FDA lists on this notice. It reports a match, a possible match (your code is part of a longer listed code) or no match. It only compares text: a notice that describes products by dates, sizes or “all lots” cannot be compared, so “no match” does not clear a product. The comparison runs in your browser and the page does not send the code anywhere, and the code stays out of the page address. Only if you press “Copy link to this result” is a link made that carries it, and whoever opens that link requests that address from this site.

When was this recall published?

FDA published recall 98132 on January 14, 2026.

Other notices of IMRIS Imaging Inc