Dexcom, Inc. recalls
8 notices naming Dexcom, Inc. as the recalling firm, since February 26, 2025. A notice covers specific products and lots, not every product of the firm.
Hazard and remedy text is quoted from the agency, unedited. The tag names the kind of risk with a word from that text. Every notice links to its official page.
Dexcom, Inc.: Brand Name: Dexcom G7 Continuous Glucose Monitoring System Product Name: Dexcom G7 US…
Hazard (FDA): Certain lots of Dexcom G7 sensors originally designated as scrap and intended for destruction were stolen during the destruction process. The sensors were later sold to pharmacies and distributors by Pharmsource, LLC…
FDAMedical devices
Dexcom Uncovers Theft of Scrapped Product, Notifies Potentially Impacted Users
Hazard (FDA): Sensors identified as scrap were diverted and sold by third-party
FDAMedical devices
Dexcom, Inc.: Brand Name: Dexcom G7 Continuous Glucose Monitoring System Product Name: Dexcom G7 CGM… and 2 more
Hazard (FDA): A software defect in which a low-priority file I/O check blocks the higher-priority thread responsible for processing estimated glucose values (EGVs) and trend arrows. When the app is running in the background, EGV…
FDAMedical devices
Dexcom, Inc.: Brand Name: Dexcom G6 Continuous Glucose Monitoring System Product Name: Dexcom G6 and…
Hazard (FDA): A software defect in version v1.15.0 of the G6 Android app can cause the app to terminate unexpectedly, which may result in the user not receiving estimated glucose values, alarms, alerts or notifications. This could…
FDAMedical devices
Dexcom, Inc.: Brand Name: Dexcom G7 Continuous Glucose Monitoring System Product Name: Dexcom G7 CGM… and 4 more
Hazard (FDA): The affected devices are the Dexcom G7 Continuous Glucose Monitoring System (CGM System) using iOS, watchOS and Android App software (versions 2.8.0 or earlier) and Dexcom ONE+ CGM System using iOS and Android App…
FDAMedical devices
Dexcom, Inc.: Dexcom G6 Glucose Receiver and 3 more
Hazard (FDA): Defective foam or an assembly error may cause the receiver speaker to lose contact with the printed circuit board, leading to missed audible alerts for low or high blood glucose values. A missed audible alert for low…
FDAMedical devices
Dexcom, Inc.: Dexcom G7 iOS Application
Hazard (FDA): A bug in the 2.7.0 version of the G7 iOS App can cause the app to enter a state where it stops updating the estimated glucose value (EGV) and continues to show this stale EGV. If the user is unaware that the EGVs are…
FDAMedical devices
Dexcom, Inc.: Dexcom G6 and 2 more
Hazard (FDA): Under very rare situations, the Dexcom G6 touchscreen receiver may not provide high or low glucose alarms/alerts as designed, which can result in two different conditions. First, if a receiver operating system .net…
FDAMedical devices